TMI 60W 12VAC Model: TM-60-12WB-1C transformer for low voltage LED lighting use.
Our productis engineered to meet the highest standards of functionality and design and its simple structure enables user to easily operate. It offers a functional intelligent photo timer sensor on 8-foot lead wire that is easly placed through a small hole in a wall or ceiling. 1. Input power cord plugged in power "120VAC 60Hz", Attach output power cable to bottom to transformer output terminal. 2. Rotay light control. The bulb will light automatically when the surrounding luminance turns dark. 3. After sense the surrounding luminance, PTS will response automatically after 30 seconds to avoid any error response due to ambiguous light. 4. Timer Control. When light are ON, the timer will start to count time. Timer can be set up from Automatic, 4,6,8 hrs. When the inner timer run out the setting hours, the lights will turn OFF automatically. During the timer working, if PTS sense the intensive luminance over 30 seconds, the lights will turn off automatically. Trun knob ”ON” directly to turn ON and “OFF” to turn off the light. (See fig3) 5. Restore automatically in 24 Hrs. The second day after the setting has completed, when PTS sense the luminance get dark, it will repeat the function same as previous setting. 6. Short-circuit protection. Check Over Current fuse if the lights do not light. Check ALL the lighting on output, OFFOutput No Power. When current fuse is blown check wiring for shorts or damage. ON Output Power "On". Incorrect hookup or defecive lighting will blow the fuse. AUTOPhoto cell Control "On". 4H, 6H, 8HPhoto cell Control "On" IMPORTANT SAFETY INSTRUCTIONS When Timer ends, output oower will Turn OFF. When applying electrical products, basic cautions should Fig 3 (Time rotary control switch) 1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS 2. Read and follow all instructions that are on the product or provided with the product. 3. For a cord-connected or direct plug-in power unit, do not use an extension cord. 4. Reference the National Electrical Code, ANSO/NFPA70,specifically for the installation of wiring and clearances from power and lighting conductors. 5. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction in your state or country. 6. For a cord-connected or direct plug-in power unit, do not install or use within 10 feet of a pool.
7. For a cord-connected or direct plug-in unit , do not use in a bathroom. 8. For a direct plug-in or cord-connected power unit marked in accordance with "WARNING: Risk of Electric Shock. Install only to a covered Class A GFCI receptacle that has an enclosure that is weatherproof with the attachment plug cap inserted or removed." 9. "WARNING: Risk of Electric Shock. Mount the unit at a height greater than 1 foot from the ground surface." 10. "WARNING: Only For Wall Mounting" 11. Suitable for both Indoor and Outdoor use. If for indoor use, transformer can be installed on a flat secure surface area or hung on a wall.
 
Wiil Power LED outdoor Lighing up to 4.8 amp with Max load of 5A

 The front and back above are power by the same transformer

|